Emerson 4500 Pacemaker User Manual


 
Reference Manual
00809-0100-4027, Rev AA
December 2005
Rosemount 4500
3-4
HART COMMUNICATOR
Menu Tree
1. Universal.
Rev.
2. Field. Dev.
Rev.
3. Software
Rev
1. Tag
2. Date
3. Descriptor
4. Message
5. Model
6. Model Number I
7. Model Number II
8. Model Number III
9. Write Protect Conf
Write Protect Local
Keys
REVISION #’S
Final Assembly
Num
Dev ID
Distributor
1. Meas Typ
2. Module config Type
3. Isoltr matl
4. Fill fluid
5. Process Connector
6. Process Conn Matl
7. O ring Malt
8. Drain Vent Matl
1. Press Alert Mode
2. Temp Alert Mode
3. CONFIG PRESS ALERT
4. CONFIG TEMP ALERT
1. Pres
2. Percent Range
3. Analog Output (AO)
4. Snsr Temp
5. SV
6. PV is
1. PRESSURE SENSOR
2. DEVICE TEMP. SENSOR
1. Date
2. Descriptor
3. Message
4. Write Protect
5. Conf Write Protect
6. Model
7. Model Number I
8. Model Number II
9. Model Number III
1. Pres
2. Percent Range
3. Analog Output (AO)
4. Snsr temp
5. SV
6. PV is
1. Tag
2. Unit
3. RANGE VALUES
4. DEVICE INFO
5. Xfer fnctn
6. Damp
7. LCD display config
1. Self test
2. Status
1. Keypad Input
2. Apply Values
1. SV DATA POINTS
2. SV Units
3. SV Xfer Function
4. SV Cutoff Mode
5. SV Low Flow Cutoff
6. SV Linear Offset
7. SV Config
1. Digital-to-Analog Trim
2. Scaled D/A Trim
1. Keypad Input
2. Apply Values
1. Keypad Input
2. Apply Values
1. Poll Addr
2. Num Req Preams
3. Burst Mode
4. Burst Option
1. FIELD DEVICE
INFO
2. SENSOR INFO
3. Self Test
4. DIAPHRAGM
SEALS INFO
1. DEVICE SETUP
2. PV
3. AO
4. PV URV
5. PV LRV
1. PROCESS
VARIABLES
2. DIAG/SERVICE
3. BASIC SETUP
4. DETAILED
SETUP
5. Review
1. TEST DEVICE
2. Loop Test
3. CALIBRATION
1. RERANGE
2. ANALOG OUTPUT TRIM
3. SENSOR TRIM
4. Recall fact trim
Online Menu
1. PROCESS
VARIABLES
2. SENSOR
SERVICE
3. Unit
1. SENSORS
2. SIGNAL
CONDITION
3. OUTPUT
CONDITION
4. DEVICE
INFORMATION
1. PROCESS
VARIABLES
2. RANGE VALUES
3. Unit
4. Transfer Function
5. Damp
6. Snsr Temp Unit
7. ALM/SAT LEVELS
1. Alarm Direction
2. High Alarm
3. Low Alarm
4. High Sat
5. Low Sat
6. Config Alarm Dir
7. Config Alarm Level
8. Config Sat Levels
1. PROCESS
VARIABLES
2. ANALOG OUTPUT
3. HART OUTPUT
4. SCALED VARIABLE
5. PROCESS ALERTS
6. VARIABLE
REMAPPING
1. Zero Trim
2. Lower Sensor Trim
3. Upper Sensor Trim
4. Sensor Trim Cal Typ
5. Sensor Trim Points
1. Pres
2. Percent Range
3. Analog Output (AO)
4. Snsr temp
5. SV
6. PV is
1. SENSOR TRIM
2. Recall Fact Trim
1. Zero trim
2. Lower Sensor Trim
3. Upper Sensor Trim
4. Snsr Trip Cal Typ
5. Sensor Trim Points
1. Snsr Temp
2. Snsr Temp Unit
1. Pressure
2. Percent Range
3. Analog Output (AO)
4. Snsr temp
5. SV
6. PV is
1. Loop Test
2. D/A trim
3. Scaled D/A Trim
4. Alarm Direction
1. Press Input 1
2. Press Input 2
3. SV Ouput 1
4. SV Output 2
1. Press Hi Alert Val
2. Press Lo Alert Val
3. USL
4. LSL
1. Temp Hi Alert Val
2. Temp Lo Alert Val
3. Snsr Temp USL
4. Snsr Temp LSL
1. PV is
2. SV is
3. TV is
4. Re-mapping
1. # of diaph seals
2. Seal Type
3. Seal Fill Fluid
4. RS Isoltr Matl