ITW Dynatec c. 1999 Page 5 - 3
TPC-2 TIMER Manual #50-05 Revised 1/99
4. The problem is in either the Output Cable or Output Device (Glue Applicator or
Automatic Tip Sealer) if the Status LED is green when the Trigger Device is activated
with the Output Cable disconnected. Employ proper electrical troubleshooting techniques
to identify the source of the problem in the cable or output device.
Program Parameters Cannot Be Modified
1. Is the DIGIT button being depressed prior to attempting to use the VALUE knob?
Many of the parameters require depressing the DIGIT button before they can be modified.
2. Is the Program Security in the LOCKED position?
The Program Security Key must be used to UNLOCK the security feature (key tab in the
vertical orientation) prior to any program modifications.
SYSTEM Parameters Cannot Be Accessed
The RUN/STOP button must be depressed until the LED above this button is dimmed in
order to access the SYSTEM parameters (i.e. PURGE, TRIG MODE, TIME RANGE,
and GLUE/PASS/START)
Glue Pattern Repeats Itself on the Product
Review the TRIGGER MODE section of this manual to assure the desired mode has been
properly selected.