ITW Dynatec c. 1999 Page 3 - 9
TPC-2 TIMER Manual #50-05 Revised 1/99
2. Rotate the VALUE knob until the desired EVENT is selected. The table below
indicates the meaning of each display setting.
EVENT Display Settings
DISPLAY MEANING
OFF
The selected CHANNEL is inactivated, no other parameter
programming will be possible for that CHANNEL
1 through 4
The remaining CHANNEL parameters (DELAY, LINE GAP, STITCH
and SPIKE TIME) will be programmed for the displayed EVENT
Delay
The TPC-2 handles DELAY times from one EVENT to the next in a cumulative fashion
as illustrated in the diagram below.
1. Depress the desired CHANNEL button until the LED to the left of DELAY is
illuminated.
2. Depress the DIGIT button the necessary number of times until the desired
programming granularity is selected (the desired place-holder digit is flashing).
3. Rotate the VALUE knob until the desired DELAY value is selected.
4. Displayed values range from 0000 to 1999. The meaning of these settings is dependent
upon the selected TIME RANGE in the SYSTEM parameters. Refer to the below table as
well as the section explaining TIME RANGE for a complete understanding of the
DELAY programming.
DELAY Display Settings
TIME RANGE
Setting
DELAY Values
0.001 0001 to 1999 (0.001 to 1.999 seconds)
0.010 0001 to 1999 (0.01 to 19.99 seconds)
1
2
3
4
E
V
E
N
T
LINE 4
DELAY 1
LINE 1
DELAY 2
LINE 2
DELAY 3 LINE 3
TRIGGER
DELAY 4