Page 3 - 6 ITW Dynatec c. 1999
Revised 1/99 TPC-2 TIMER Manual #50-05
TIME RANGE Display Settings
DISPLAY MEANING
0.001
Time Range Selection between 0.001 and
1.999 seconds
0.010
Time Range Selection between 0.01 and
19.99 seconds
NOTE: Maximum time settings (i.e. 1.999 or 19.99 seconds) represent the maximum
allowed cumulative time for DELAY and LINE duration of all four EVENTs in a
CHANNEL
Glue/Pass/Start
The TPC-2 offers a Palletizing feature that provides the capability of gluing a specified
quantity of items, based upon Trigger inputs, then “passing” (allowing sensed product to
pass under the applicator with no glue being applied) a specified quantity of items, also
based upon Trigger inputs. The Operator can program both the quantity of product to be
“glued” and “passed” along with specifying whether the process should begin with the
“glue” or the “pass” count.
1. Depress the SYSTEM button until the yellow LED to the left of GLUE/PASS/START
is illuminated. The display will show OFF if the Palletizing program in not currently
active.
Glue
2. Depress the DIGIT button. The display will show G.000 with the digit furthest to the
right flashing. This display allows the programming of the quantity of items to be
“glued”. Depressing the DIGIT button additional times will change the granularity of the
“glued” quantity setting.
3. Rotate the VALUE knob until the desired “glued” quantity is selected. (Example:
G.040 indicates that forty consecutive items will be glued).
NOTE: Selection of the value G.000 for this parameter will set the palletizing feature to
OFF, regardless of any PASS values that may be programmed.
Pass
4. Depress the SYSTEM button once. The display will now show P.001 or some other
similar value.
5. Depress the DIGIT button. The digit furthest to the right will commence flashing. This
display allows the programming of the quantity of items to be “passed”. Depressing the
DIGIT button additional times will change the granularity of the “passed” quantity
setting.