Dynatech PN 106082: 115v Pill Reminder Device User Manual


 
Page 3 - 2 ITW Dynatec c. 1999
Revised 1/99 TPC-2 TIMER Manual #50-05
Programming Conventions
The TPC-2 employs the following programming conventions:
1. All CHANNEL modifications are performed on the Program displayed (Pr-1, -2, -3 or
-4) when the MEMORY LED is illuminated.
2. Depressing the CHANNEL 1 or CHANNEL 2 buttons allows programming of the
parameters for that channel of the selected Program (Pr-1, -2, -3 or -4).
3. Depressing the SYSTEM button allows programming of the parameters that pertain to
the entire glue system, regardless of the Program (Pr-1, -2, -3 or -4) or CHANNEL
selected.
4. Depressing the DIGIT button allows selection of the “granularity” of the displayed
parameter as it is being modified. (i.e. depressing the DIGIT button until the “100’s”
place holder is flashing will result in increments/decrements of 100 units at a time,
depressing the DIGIT button until the “1’s” place holder is flashing will result in
increments/decrements of single units at a time, etc.).
5. Rotation of the VALUE knob allows the actual modification of displayed values.
6. The glue system will not operate unless the LED above the RUN/STOP button is
illuminated.
7. Modification of the CHANNEL parameters while the glue system is operating will
result in real-time adjustments to the glue pattern. This allows the operator the ability to
“fine-tune” the program settings while the system is operating.
8. No SYSTEM parameters may be accessed while the LED above the RUN/STOP
button is illuminated with the exception of the PALLETISING COUNT.
9. Only the active Program (Pr-1, -2, -3 or -4) may be modified while the glue system is
operating.