Dynatech PN 106082: 115v Pill Reminder Device User Manual


 
Page 3 - 8 ITW Dynatec c. 1999
Revised 1/99 TPC-2 TIMER Manual #50-05
volatile”, the settings are retained even when TPC-2 Control Unit input power is lost or
the power switch is turned off.
1. Depress the SYSTEM button until the LED above the button is no longer illuminated
and the green LED to the left of the MEMORY parameter is illuminated.
2. Rotate the VALUE knob until the desired Program (Pr – 1 through Pr – 4) is
displayed.
NOTES:
a. The MEMORY setting may only be modified when the TPC-2 Control Unit is in the
STOP mode (the LED above the RUN/STOP button is not illuminated).
b. Modifications to CHANNEL parameters affect only the active Program selected via the
MEMORY parameter.
Programming Glue Pattern (CHANNEL) Parameters
Programming of a glue pattern into the TPC-2 Control Unit is accomplished by
depressing either the CHANNEL 1 or CHANNEL 2 button so that the red LED above the
button is illuminated. Activation of CHANNEL parameters is signified via illumination
of the LED to the left of the specific parameter (EVENT, DELAY, LINE, GAP, STITCH
and SPIKE TIME).
NOTES:
a. All CHANNEL parameters may be modified regardless of whether the TPC-2 Control
Unit is in the RUN or STOP mode.
b. All CHANNEL parameters are stored in “non-volatile” memory, the settings are
retained even when TPC-2 Control Unit input power is lost or the power switch is turned
off.
c. Modification to CHANNEL parameters may only be undertaken when Programming
Security is in the UNLOCKED position.
d. CHANNEL 1 and CHANNEL 2 parameters are independent of each other, however the
programming procedure for each CHANNEL is exactly the same.
Event
Each CHANNEL of each Program has up to four EVENTs. An EVENT is defined as a
DELAY (skip) duration followed by a LINE (glue) duration.
1. Depress the desired CHANNEL button until the LED to the left of EVENT is
illuminated.