Digi DC-190 Scale User Manual


 
8 DC-190 Ultra Count Installation Manual
5. Place scale on side. Remove four top cover
screws (shown in Figure 2-7). Set scale on
legs and remove top cover.
Figure 2-7. Location of Top Cover Screws
6. Disconnect black () and red (+) electrical
leads from battery (see Figure 2-8). Remove
existing DC battery pack. Attach red lead to
positive (+) side of battery.
7. Attach black lead to negative () side of
battery.
8. Place new DC battery pack in battery
compartment.
Figure 2-8. Battery Installation
9. Reassemble scale in the reverse order that it
was disassembled.
10. Remove setscrew to unlock scale before
placing the scale into service.
If the DC-190 scale is operated with the
battery pack removed, isolate the
positive (+) and negative (–) leads so
that they do not make contact with each other or any part
of the scale frame or any sensitive electronic components.
2.3.3 DC Battery Operation
To power-up the DC-190 using the optional battery:
1. Remove AC power cord from bottom of scale.
2. Turn battery switch to ON (located on the
bottom left-hand side of the scale base).
3. Press
ON/OFF and allow scale to warm up for
10 minutes. The display momentarily shows
revision number, shows all digits from 0 to 9
in a count-up mode, goes blank, shows all 8s,
and then enters normal weighing mode.
2.3.4 Battery Charging
A fully charged battery allows for approximately 4
hours of continuous use. Refer to SPEC 1 (Power Auto
Off function) for extended hours of use. It will take
approximately 8 hours to fully recharge a battery that
has been completely dissipated. The console must be
connected to the base during the recharge cycle and
the AC power cord must be plugged in.
NOTE: Do not store the scale without turning off the
battery power switch! When the battery switch is ON and
the AC is not connected, a low level battery current will flow
even if the display is OFF. To prevent battery discharge
when stored, turn the battery switch OFF whenever the unit
is not in use.
2.4 Setting Time and Date
You can set the time and date printed on DC-190 print
tickets. SPEC 5, bits 0 and 1 list three sequence
variations of year, month, day that are available to
enter dates into the DC-190 counting scale. Printed
dates always appear in mmddyy format.
To set the date (month, date, and year) and time:
1. Press the
MODE key.
2. Press the
–/DATE key. The displays shows the
date, day, and time.
3. Press the
–/DATE key again. Enter month, day,
year (mmddyy) on the keypad.
4. Press the
–/DATE key. Enter the day (0=Mon,
1=Tue…6=Sun.
5. Press the
–/DATE key. Enter the time of day
using the 24-hour clock. For example, enter
1:35 p.m. as 1335.
6. Press the
*/PROG key to store the setting, or
press the
–/DATE key to exit without saving
time and date.
TOP COVER SCREWS
BATTERY
POSITIVE (+)
TERMINAL
NEGATIVE (-) TERMINAL
Caution