Digi DC-190 Scale User Manual


 
32 DC-190 Ultra Count Installation Manual
NOTE: When you hear the beep, the display shows the last item code in memory. Press the key to review the
item codes in reverse order.
4. Press the MODE key to return to Step 1.
5. Press the
MODE key again to return to weighing mode.
Delete Item Memory
The following procedure describes the steps used to delete all information stored within each item code (unit
weight, tare weight, part number, quantity, part, setpoints, and lot number) or any specific information stored
within each item code. It also explains the keystrokes required for resetting the sequence number, or deleting all
setpoints, global to the scale, but not tied to a specific item code.
1. Press the
MODE key. The WEIGHT display will show ProG and the QUANTITY display shows C XX.
2. While pressing the
REZERO key, enter the sequence as shown in Table 7-2 to delete the specified
information. The table shows the prompting that will take place on the weight and quantity displays to
ensure that the proper keystrokes have been performed.
NOTE: If an error was made entering data and the display is prompting you to clear information that is not to be
cleared, press the
MODE key and return to Step 1.
3. Press the CLEAR key to delete the information.
4. Press
MODE to exit programming mode.
7.3 Using Item Code in Normal Mode
The following paragraphs describe the procedure to recall item codes, recompute item code unit weights, set new
item codes, and inventory operations related to the item code quantity. All storage operations are done while the
scale is in the normal mode.
Recalling Numeric Item Codes using Item Code Number
1. Enter item code number using numeric keypad.
2. Press the
CODE key. The scale will recall all information stored with the item code and automatically
return to the normal mode.
Recalling Alphanumeric Item Codes using Teraoka Code
1. Press the . (decimal) key. The WEIGHT display prompts t-C 01, the QUANTITY display shows CodE, and
the
UNIT-WEIGHT display prompts 00-.
2. Enter the values equivalent to the digits to be entered using the Teraoka Code. For example, to recall
Item Code 123, enter: [
31], [32], [33], [01], [02], [03] = 123ABC.
3. Press the
CODE key. The scale will recall all information stored with the item code and automatically
return to the normal mode.
Delete Item Memory Sequence WEIGHT Display QUANTITY Display
Delete all memories ••0 ALL CLEAr
All item quantity in stock ••1 InVEnt CLEAr
All item unit weights ••2 UnIt u
CLEAr
All item tare weights ••3 TArE CLEAr
All item part numbers ••4 P-no CLEAr
All item setpoints ••5 P-SP CLEAr
All item names ••6 P-nAmE CLEAr
Reset SEQ numbers ••7* SEQ no CLEAr
Delete all setpoints (global) ••+ SEt P CLEAr
*Use for BCP-30 printer
Table 7-2. Deleting Item Codes in Memory