AMX RE-DM6 Light Therapy Device User Manual


 
AMX RADIA Lighting Programming
43
RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules
Phase Query
This function queries the current state of the phase detection system.
Phase zero-crossing detection occurs at all times.
In the presence of a phase/zero-cross error, the AxLink LED will blink very fast (>10Hz) and all
string responses (where existent) will be "PHASE ERROR!".
Version Query
This function queries the Radia for its firmware version.
Factory Default
This function commands the Radia to restore all factory defaults.
Phase Query
String: [<pack>]Y
Response: P<pack>: <pass/fail> 1<state1> 2A<state2A> 2B<state2B> 3<state3>
The <pass/fail> item will either be 'OK' or 'FAIL' to indicate an overall condition.
The <state> items are phase specific to indicate which phase is failing.
The <state> will either be 'Y' for okay or 'N' failure.
Example:
SEND_STRING Radia,"'Y',13" check phase status
Response: "12,'P01: OK 1Y 2AN 2BN 3N',13,10,'?'" Good response
SEND_STRING Radia,"'Y',13" check phase status
Response: "12,'P01: FAIL 1Y 2AN 2BN 3Y',13,10,'?'" Fail on 2A and 2B
Version Query
String: <pack>VER
Response: P<pack> <version string>
Example:
SEND_STRING Radia,"'VER',13" Request version
Response: "12,'P01 v3.14',13,10,'?'"
If <p> is specified, it must be 1 (e.g. 1Y).
Factory Default
String: FACTORY
Response: None
Example: SEND_STRING Radia,"'FACTORY',13" Restore Factory Defaults
Response: None