AMX RADIA Lighting Programming
41
RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules
Dimmer Status
This function returns the status of the specified dimmer.
The use of multiple dimmers (e.g. 'A', '&', and '-') are not allowed with this function, and their use
will return an error.
If the level of the dimmer is undefined, the level is reported an 'UN'.
This is the only method used to determine if a level is undefined. For example, the response to the
command above would be: "12,'CHAN:3 CURV:1 LEV:UN',13,10,'?'"
Reboot
This function reboots the dimmer and initializes it to its power-up state. The device will go off-line with the
master and return on-line.
If <pack> is specified, it must be 1.
Set Default Level Time
This function sets the time taken for a level to change from its current level to a new level when using a level
command.
Set Default Preset Time
This function sets the time taken for a preset recall to ramp when no time is specified to override this default
time.
Dimmer Status
String: <dimmer>
Response: CHAN:<dimmer> CURV:<curve> LEV:<level>
Example: SEND_STRING Radia,"'3',13" Request dimmer 3 status
Response: "12,'CHAN:3 CURV:1 LEV:43',13,10,'?'"
Reboot
String: [<pack>]QQQ
Response: None
Example:
SEND_STRING Radia,"'QQQ',13" Reboot dimmer
Response: none
Set Default Level Time
String: LT<time>
Response: 'LEVEL TIME SET AT <time>'
Example:
SEND_STRING Radia,"'LT3',13" Set default level ramp time to 3 seconds
Response: "12,'LEVEL TIME SET AT 003',13,10,'?'"
SEND_STRING Radia,"'LT0',13" Set default level ramp time to 0 seconds
(instantaneous)
Response: "12,'LEVEL TIME SET AT 000',13,10,'?'"
Set Default Preset Time
String: PT<time>
Response: PRESET TIME SET AT <time>
Example:
SEND_STRING Radia,"'PT4',13" Set default preset ramp time to 4 seconds
Response: "12,'PRESET TIME SET AT 004',13,10,'?'"