Agilent Technologies FS2334 Thermometer User Manual


 
30
Export
This function takes the data captured and exports it in .csv format to a location the user
selects.
Repetitive Run
This function allows the user to set-up the tool to trigger the logic analyzer a predefined
number of times and capture data incrementally on each run. Please note this function
does not work in Off Line mode.
Timing Analysis
This window tab provides an analysis of each Data bit’s window during every data burst
across an entire TimingZoom trace. The user can set a threshold criteria in this window
and then select whether the data windows to be identified should be equal to, greater
than or equal to, or less than or equal to that value. All Data bits during any burst
captured in a TZ trace will be listed in the Timing Analysis window.
Additionally, the tool provides some overall statistics on what was measured in the TZ
trace that was analyzed. This includes the number of Read and Write strobes analyzed,
the % of data strobes with data transitions occurring; as well as, the maximum, minimum
and average Data Bit widths across ALL bits during ALL bursts in the TZ trace.
Export
This function takes the data captured and exports it in .csv format to a location the user
selects.