Adaptec 2200S Microscope & Magnifier User Manual


 
4-31
Using the Command Line Interface
controller set automatic_failover
[/failover_enabled{=boolean}]
Turns on or off automatic failover for the controller.
Switches
/failover_enabledSpecifies whether to turn on or off
automatic failover on the controller. Specify 1 to enable, 0 to
disable. The default is 0.
controller set container_verify
[/verify_enabled{=boolean}]
Turns the container verify task on or off.
Switches
/verify_enabled—Specifies whether to turn on or off the
container verify feature. The command defaults to TRUE,
which means the command turns on the container verify
feature.
controller show automatic_failover
Displays the automatic failover status (enabled or disabled)
for the controller.
controller show channels
Displays all of the channels on the controller with the
characteristics of each channel.
controller show container_verify
Displays the status of the container verify status.
UG.book Page 31 Saturday, October 26, 2002 12:08 PM