4-12
Adaptec SCSI RAID 2120S/2200S Software User’s Guide
Example of disk list:
AAC0> disk list
Executing: disk list
C:ID:L Device Type Blocks Bytes/Block Usage Shared
------ ----------- -------- ----------- ----------- ------
2:01:0 Disk 17783240 512 Initialized NO
2:02:0 Disk 17783240 512 Initialized NO
■
disk show defects
Example of disk show defects:
AAC0> disk show defects /full=true (3,1,0)
Executing: disk show defects /full=TRUE
(CHANNEL=3,ID=1,LUN=0)
Number of PRIMARY defects on drive: 5
Defect 1 at cylinder 229, head 7, sector 203
Defect 2 at cylinder 575, head 0, sector 219
Defect 3 at cylinder 576, head 0, sector 55
Defect 4 at cylinder 578, head 0, sector 238
Defect 5 at cylinder 579, head 0, sector 74
Number of GROWN defects on drive: 0
■
disk verify
Example of disk verify:
AAC0> disk verify
Disk Attribute: Indicates:
disk defects
■ Total number and location of primary defects
(defects that originate during manufacturing)
■ Total number and location of grown defects
(defects that originate after manufacturing)
Disk Attribute: Indicates:
disk defects
■ Total number and location of primary defects
(defects that originate during manufacturing)
■ Total number and location of grown defects
(defects that originate after manufacturing)
UG.book Page 12 Saturday, October 26, 2002 12:08 PM