Adaptec SCSI RAID 2120S/2200S Software User’s Guide
The following rules apply to migration:
1 The capacity of the new array must match or exceed the
capacity of the current array.
2 If the capacity and/or RAID type of the new array requires
greater total drive capacity than the current array, the
additional capacity must be on drives that are not already used
in the current array.
To modify an array:
1 Click Modify.
2 Select the array that you wish to modify.
3 Select the RAID level that you want to migrate the array to, or if
you want to expand the capacity of the existing array, select the
current RAID level.
Optionally, click Advanced to select the stripe size you want the
new array to use, or that you want to change the existing array
to.
4 If necessary, select the additional drive(s) required for capacity
expansion, or necessary to support the new RAID level.
Optionally, click Advanced to adjust the priority for the task.
5 Click Finish.