Schneider Electric 9070 Personal Lift User Manual


 
Industrial Control Transformers
Type T Transformers
9
08/2005
© 1999–2005 Schneider Electric All Rights Reserved
120 Volt Control Secondary
Voltage and Connection Options
Voltage
Code
Voltages Connections
Primary Secondary Primary Secondary
D3 208 120
Connect to H1 and H2 Connect to X1 and X2
D4 277 120
D5
550
575
600
110
115
120
D6 380 110
D17 415 110
D24
110
115
120
110
115
120
D93 200 115
D103 400 120
H1
X2 X1
H2
Dimensions
VA
Catalog
Number
1
Figure
Acc.
Key
ABCEF Slots
UL CE IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
25 25 9070T25t 1 I 3.09 79 3.00 76 2.58 66 2.00 51 2.50 64 0.20 x 0.38 5 x 10
50 50 9070T50t 1 I 3.09 79 3.00 76 2.58 66 2.00 51 2.50 64 0.20 x 0.38 5 x 10
75 75 9070T75t 1 I 3.34 85 3.38 86 2.89 73 2.38 61 2.81 71 0.20 x 0.48 5 x 12
100 100 9070T100t 1 I 3.34 85 3.38 86 2.89 73 2.38 61 2.81 71 0.20 x 0.48 5 x 12
150 150 9070T150t 1 I 3.59 91 3.75 95 3.20 81 2.88 73 3.13 80 0.20 x 0.38 5 x 10
200 200 9070T200t 1 I 3.59 91 3.75 95 3.20 81 2.88 73 3.13 80 0.20 x 0.38 5 x 10
250 160 9070T250t 2 I 5.301353.75953.21822.88733.13800.20 x 0.385 x 10
300 200 9070T300t 2 I 4.74 120 4.50 114 3.84 98 2.56 65 3.75 95 0.20 x 0.38 5 x 10
350 250 9070T350t 2 I 5.11 130 4.50 114 3.84 98 3.00 76 3.75 95 0.20 x 0.38 5 x 10
500 300 9070T500t 2 I 5.49 139 4.50 114 3.84 98 3.56 90 3.75 95 0.20 x 0.38 5 x 10
750 500 9070T750t 2 I 5.61 143 5.25 133 4.51 115 3.43 87 4.38 111 0.28 x 0.56 7 x 14
1000 630 9070T1000t 2 I 6.30 160 5.25 133 4.51 115 4.31 109 4.38 111 0.28 x 0.56 7 x 14
1500 1000 9070T1500t 2 I 5.92 150 7.06 179 6.17 157 4.13 105 5.81 148 0.28 x 0.56 7 x 14
2000 1500 9070T2000t 2 I 7.17 182 7.06 179 6.17 157 4.56 116 5.81 148 0.28 x 0.56 7 x 14
3000 2000
9070T3000t
2
2 I 6.38 162 9.00 229 7.63 194 4.63 118 7.63 194 0.44 x 1.13 11 x 29
9070T3000t
3
3 I 7.24 184 9.00 229 8.75 222 4.63 118 7.63 194 0.44 x 1.13 11 x 29
9070T3000D24 3 N/A 8.08 205 9.00 229 8.75 222 4.63 118 7.63 194 0.44 x 1.13 11 x 29
5000 3000
9070T5000t 3 I 9.15 232 9.00 229 8.75 222 6.56 167 7.63 194 0.44 x 1.13 11 x 29
9070T5000D24 3 N/A 9.99 254 9.00 229 8.75 222 6.56 167 7.63 194 0.44 x 1.13 11 x 29
1
Complete the catalog number by replacing the t with the correct Voltage Code from the “Voltage and Connection Options” table above.
2
Complete the catalog number by replacing the t with Voltage Code D3 or D4 from the “Voltage and Connection Options” table above.
3
Complete the catalog number by replacing the t with Voltage Code D5, D6, D17, D93, or D103 from the “Voltage and Connection Options” table above.
Figure 3
B
D
A
E
F
C
D
A
B
F
E
C
Figure 2Figure 1
C
B
D
A
E
F