Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 2: Mechanical installation
3-9000-765 Rev H May 2015
Appropriately rated lifting slings 41
3. NEVER attempt to lift the meter using only one sling around the meter. Always use two
slings wrapped around each end of the body as shown below. A choker style sling is
recommended using a spreader bar.
Figure 2-11 Correct sling attachment
4. Visually inspect the slings prior to use for any signs of abrasion or other damage. Refer
t
o
the sling manufacturer's procedures for proper inspection of the particular sling you
are using.
5. Only use slings with ratings that exceed the weight to be lifted. Reference your
co
mpany's standards for safety factors that must be included when calculating the load
rating.