Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual Section 1: Introduction
3-9000-765 Rev H May 2015
Daniel 3812 Liquid Ultrasonic Flow meter design 11
Figure 1-7 Remote mount electronics assembly with split shrouds
A. Explosion-proof transmitter enclosure (CPU Module, Power Supply, I.S. Barrier Board
B. Intrinsically-safe base enclosure includes Acquisition Module
C. Acquisition cable conduit
A.
B.
E.
D.
C.
D. Junction box
E. Meter - body and split shrouds for transducer and cable assemblies
Backplane board, optional LCD Board with glass endcap)