14 Meter specifications
Section 1: Introduction Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual
May 2015 3-9000-765 Rev H
Meter Performance (continued)
Flange types ANSI classes - 150, 300, 600 and 900
Raised face or RTJ
Specific Gravity 0.35 to 1.50
Accuracy Limits Accuracy limits typically are:
± 2% without a flow calibration, ± 0.3% with flow calibration
Minimum operating
pressure
0 psig
0 barg
Electronic specifications
Power Meter
10.4 VDC to 36 VDC measured at the meter terminals
1
11 W maximum power consumption
Serial cable
Belden #9940 or equivalent (22 gauge)
Capacitance (pF/m) 121.397 (conductor to conductor)
Capacitance (pF/m) 219.827 (conductor to other conductor and shield)
Resistance (DC) DCR @ 20 °C (Ohm/km) 48.2307
Nominal Outer shield resistance - DCR @ 20°C (Ohm/km) 16.405
Operating voltage - 300 V RMS (UL AWM Style 2464)
Current 2.4 Amps per conductor @ 25°C (recommended)
Ethernet cable
Cat-5 Standard 100Mbps
Frequency (
see Table 3-1)
22 AWG wire characteristics are as follows:
Capacitance = 20 pF/ft or 20 nF/1000 ft (between two wires)
Resistance = 0.0168 Ohms/ft or 16.8 Ohms/1000 ft
Pull-up voltage is 24 VDC
Temperature
flameproof transmitter
electronic enclosure and
bas
e electronic enclosure
Ambient: -40
o
F to 140
o
F (-40
o
C to 60
o
C)
Storage: -58
o
F to 185
o
F (-50
o
C to 85
o
C)
Note: The transmitter electronics enclosure and base enclosure must be remote mounted if the
op
erating temperature exceeds 140
o
F (60
o
C).
Transducers
LT-10 and LT-11 Operating temperature range with NBR O-rings
-58
o
F to +275
o
F (-50
o
C to 135
o
C)
LT-10 and LT-11 Operating temperature range with FKM O-rings
-40
o
F to +302
o
F (-40
o
C to +150
o
C)
Note: The process temperature must not exceed th
e operating temperature range of
the transducers.
Note: LT-10 transducers are designed for 4 inch to 10 inch meters. LT-11 transducers are designed
f
or 12 inch and larger meters.
Note: The ultrasonic transducers are not intended for use across boundary walls of different
h
azardous area classifications. The transmitter electronics cannot be remote mounted from
a Division 1 classification to a Division 2 area to meet an area classification.
Acquisition Cable
Total cable length between the Acquisition Module and ultrasonic transducers must not
exceed 15 feet (4.7 meters) when using the remote mount option (
see Figure 1-7)
Table 1-2 Meter specifications