Sterling SDD 1 SGM Microscope & Magnifier User Manual


 
·
Ex tru sion with ex ter nal set value 0-10 V
S 150 jumper as sign ment
Ju1: 1-2: Mi cro pro ces sor in power save mode, open (stan dard)
Ju2/3: 1-2 + 2-4: Ma te rial sen sor with open col lec tor out put
2-3 + 4-5: Ma te rial sen sor with source driver (stan dard)
Ju4/6: 1-2: Ex ter nal RS422 sup ply
2-3: In ter nal RS422 sup ply (stan dard)
Ju5: 1-2: Set value 0-10 kHz (stan dard),
2-3: Set value 0-10 V, 0-20 mA
Ju7: 1-2: Set value 0-20 mA,
2-3: Set value 0-10 kHz (stan dard) or 0-10 V
Ju10: Equip ment sup ply volt age 115 V
Ju11: Equip ment sup ply volt age 230 V (stan dard)
176-1MS
SDD 1 SGM
Elec tri cal ma nu al 10-6
J15 J16 J8 J9 J10 J1 1 J12 J13 J14 J17
Ju7
1
Ju2
Ju3
1
1
Ju5
1
Ju4
Ju6
1
1
Ju1
F2
F3
Ju10
115V
Ju11
230V
F7
F1
F5
F4
* *
U
0-10V
+
-
* from serial number 031.03-0108162090 onwards 5 terminals