Sterling SDD 1 SGM Microscope & Magnifier User Manual


 
7. Tech ni cal Data
7.1. SDD 1 SGM
Ba sic Ver sion
Com po nents to dose gran u late, mi cro-batch/pel lets or pow der (please spec ify re quire ment)
Quick dis con nect for change over/clean ing
Sam pling tube for sim ple cal i bra tion
Abil ity to han dle ma te ri als up to 80 °C (176 °F)
Con nec tion wire to pro cess ing ma chine
Op er ating volt age ei ther 230 +/- 10 %, AC, Sin gle phase, 50/60Hz
0.2 kW op er at ing load
Weight 23 kg/51 lbs
Noise level with gran ules/pow der max. 65 dB(A) (de pend ing on the ma te rial)
Min. shot weight* 5 g (0.01 lbs)
Max. shot weight* 6500 g (6.5 lbs.)
*All feed rates are ap prox i mate, ac tual feed rates will vary ac cord ing to the feed sta tion, ma te rial,
flow prop er ties and par ti cle size.
Op tional Fea tures
Spare sta tion for im me di ate change over for pel lets or pow ders
Op tion for abra sive ma te ri als
Hop per load ers for au to matic re fill
Extern re fill ing sys tems
Low level sen sors
Spe cial volt age
176-1MS
SDD 1 SGM
Tech ni cal Data 7-1