“A0008"
The screw re tract time of the pro cess ing ma chine in shorter than 0.1 sec onds.
The unit can not be ope ra ted in com bi na ti on with this pro ces sing ma chi ne.
“A0009"
The cal cu la ted speed of the mo tor is eit her too high or too low.
Check ba sic pa ra me ter set ting and re ci pe, mo di fy if ne ces sa ry.
“A0010"
The feed sta ti on is not able to me ter the de si red re ci pe.
Check ba sic pa ra me ter set ting and re ci pe, mo di fy if nec es sary.
“A0011"
The raw ma te ri al pro be is not co ver ed.
Re fill ma te ri al.
“A0012"
The ad di ti ve pro be is not co ver ed.
Re fill ma te ri al.
F
The do sing pro cess will not be in ter rup ted.
“A0014"
Po wer fail ure.
“A0015"
EE PROM data loss, EE PROM not pro gram med.
Ster ling Ser vi ce.
“A0016”
No com mu ni ca tion be tween HOST and unit.
Check ca ble fit tings.
Ster ling Ser vice.
176-1MS
S 150
Put ting into op er a tion 3-26