Sterling SDD 1 SGM Microscope & Magnifier User Manual


 
4.7. Ex change able sta tions
Dosing discs of the same type may be ex changed for each other with out any prob lems.
If dos ing discs with a dif fer ent com part ment num ber are in stalled, this has to be en tered in the
con trol sys tem.
En ter the (pre lim i nary) cal i bra tion value of the freshly in stalled dos ing disc
(* = bulk den sity 550 g/l (35lbs/ft
3
), ** = bulk den sity 700 g/l) (44lbs/ft
3
).
Feed sta tion Num ber of dos ing com part ments Pre lim i nary cal i bra tion value
SDD30-030672 72 *1.5 , **2.0
SDD30-051040 40 *4.0 , **5.0
SDD30-051725 25 *7.0 , ** 9.0
SDD30-051818 18 *13.0 , **17.0
SDT30-101820 20 *28.0 , **35.0
SDT30-203012 12 *93.0 , **118.0
SDT30-204010 10 *148.0 , **190.0
Ex e cute “cal i bra tion” to de ter mine the fi nal cal i bra tion value.
F
When sav ing rec i pes, note the dos ing disc by means of which the cal i bra -
tion was real ised.
Mind that the ap pro pri ate dos ing disc has to be in stalled when call ing up
stored rec i pes.
176-1MS
SDD 1 SGM
Main te nance 4-15