Ter mi nal As sign ment S150 (115/230 V), from
se rial num ber 031.03-0108162090 on wards
From the se rial num ber cited above on wards the
blend ing unit and alarm re lay is once again im ple -
mented as a change-over con tact on the J9 or J8
ter mi nal.
The max. ter mi nal load con sists of 230 V/2A.
When the blend ing unit is con fig ured
(from soft ware P2.08, E2.08 on wards):
ac ti vated J9 3-4 closed, 3-5 open,
non-op er a tive sta tus: J9: 3-4 open, 3-5 closed
(If C150 is be ing me tered and dur ing the run on
time)
When the blend ing unit is not con fig ured
(from soft ware P2.08, E2.08 on wards):
ac ti vated J9 3-4 closed, 3-5 open,
non-op er a tive sta tus: J9: 3-4 open, 3-5 closed
(When the ‘RUN’ key is pressed (ready for op er a -
tion)
Alarm (from soft ware P2.08, E2.08 on wards):
ac ti vated J8: 3-4 open, 3-5 closed
If an er ror oc curs: J8: 3-4 closed, 3-5 open
An open ing func tion for the alarm re lay can also
be set in the equip ment con fig u ra tion:
F
Mark the func tion “alarm out put is
also switched in case of power fail -
ure” see page 7, chap ter 3: de ter min -
ing the con fig u ra tion value”.
Alarm (from soft ware P2.08, E2.08 on wards):
ac ti vated J8: 3-4 closed, 3-5 open
If an er ror oc curs J8: 3-4 open, 3-5 closed
176-1MS
SDD 1 SGM
Elec tri cal ma nu al 10-4
J9
1
2
3
4
4
3
2
230V: N
Mischer
230V: L1
2AT
PE
F4
5
J8
1
2
3
4
4
3
2
230V: N
Alarm
230V: L1
2AT
PE
F5
5
&
Mischer = mixer
Alarm = alarm