7.2. Con trol unit S 150
Ba sic equip ment
• 5 digit LED dis play
• Mem ory backup for rec ipe and data stor age
• Dry con tact cy cle sig nal in put
• In put for level probe for both raw ma te rial and ad di tives
• IP64 shield ing
• short cir cuit proof out puts
• Op er ates be tween 0°C to +50°C (32 to 120° F)
• Stor age tem per a ture range -20 to +70° C (-4 to +160°F)
• Op er ating volt age 230 VAC ±10 %, 50/60 Hz
• Con nected load of 100 W max i mum dur ing op er a tion
• Dry con tact alarm out put
• Ther mal de vice pro tec tion
Op tional equip ment
• RS422/465 for Euromap 17 pro to col in ter face
• Spe cial volt age avail able
Func tion al ity
• Di rect in put of de sired ad di tive per cent ages
• Au to matic cal cu la tion of cal i bra tion val ues for dos ing
• Op er ating con di tions shown via sym bols
• Dis play of ad di tive con sump tion
• Stor age of up to 10 rec i pes
176-1MS
SDD 1 SGM
Tech ni cal Data 7-2