Linear PERS-4200 Series Medical Alarms User Manual


 
36
18. Appendix B - Mode Table
CONSOLE OPERATING MODE
HOME MODE
AWAY MODE
(Overrides Night Mode)
NIGHT MODE
Reports to Central Station
Voice Announcement
Starts 2-Way Audio
Reports to Central Station
Voice Announcement
Starts 2-Way Audio
Reports to Central Station
Voice Announcement
Starts 2-Way Audio
SYSTEM EVENT
Fire & CO Alarms
Ye s Ye s ~ If Enabled
[6]
Ye s Ye s ~ If Enabled
[6]
Ye s Ye s ~ If Enabled
[6]
Fire & CO Supervisory
Timeout
[2]
Ye s ~ If Enabled
[8]
N/A
Ye s No
N/A
Ye s No
N/A
Fire & CO Sensor Low
Battery
[2]
Ye s ~ If Enabled
[8]
N/A
Ye s No
N/A
Ye s No
N/A
Console (HELP button) Alarm
Ye s Ye s ~ If Enabled Ye s Ye s ~ If Enabled Ye s Ye s ~ If Enabled
Emergency Sensor Alarm
Ye s Ye s ~ If Enabled
[6]
Ye s Ye s ~ If Enabled
[6]
Ye s Ye s ~ If Enabled
[6]
Emergency Sensor
Supervisory Timeout
[2]
~ If Enabled ~ If Enabled
[8]
N/A
No
[1]
No
[1]
N/A
~ If Enabled No No
Emergency Sensor Low
Battery
[2]
Ye s ~ If Enabled
[8]
N/A
Ye s No
[1]
N/A
Ye s No
N/A
Console Trouble
[2] & [5]
Ye s
~ If Enabled
[8] & [9]
N/A
Ye s No
N/A
Ye s No
N/A
Communication Status
(telephone/cell)
No Ye s
N/A
No Ye s
N/A
No No
N/A
Module Status
N/A
Ye s
N/A N/A
No
N/A N/A
No
N/A
Activity Monitor
Ye s Ye s ~ If Enabled
[7]
No No No Ye s Ye s ~ If Enabled
[7]
Temperature Alarms
~ If Enabled
[4]
~ If Enabled
[4]
~ If Enabled
[4]
~ If Enabled
[3]
~ If Enabled
[3]
~ If Enabled
[3]
~ If Enabled
[3]
~ If Enabled
[3]
~ If Enabled
[3]
Missed Reminder Messages
Yes
[11]
Ye s ~ If Enabled No No No Yes
[11]
Ye s ~ If Enabled
Entering Mode
Ye s
From Away
Mode Only
[10]
N/A
Ye s Ye s
N/A
From Away
Mode Only
From Away
Mode Only
N/A
Mode Table Notes:
• [1] Setting the Console in Away Mode clears all supervisory events for
emergency sensors only. Supervisory timers for Smoke detectors, CO
detectors, and activity monitor sensors are not affected; switching to Home
or Away Mode constitutes activity.
[2] Supervisory events are reported by automatic status reports regardless
of the global REPORT SUPERVISORY EVENTS setting. Also, AC power
loss events are reported by automatic status reports regardless of the global
REPORT AC FAIL setting. Both settings are on the Reporting Options tab.
• [3] If ENABLE HOME MODE ONLY is selected for TEMPERATURE LIMIT
SETTINGS on the Console tab, temperature alarms will not occur in this
mode. Select ENABLE to allow temperature alarms in this mode.
• [4] Either ENABLE or ENABLE HOME MODE ONLY needs to be selected
on the Console tab for TEMPERATURE LIMIT SETTINGS to allow
temperature alarms.
• [5] Console supervisory faults are always reported, but not annunciated in
Away Mode and Night Mode.
• [6] To start a two-way audio session after a report is triggered by an
emergency alarm sensor, two-way audio must be globally enabled in
TWO-WAY AUDIO MODE on the Reporting Options tab and enabled for
the sensor’s zone with the TWO-WAY AUDIO check box on the Sensors tab.
• [7] For activity sensors, two-way audio is enabled globally in TWO-WAY
AUDIO MODE on the Reporting Options tab regardless of the activity
sensor’s zone setting with the TWO-WAY AUDIO check box on the Sensors
tab.
[8] To enable Console/sensor zone low battery and sensor zone supervision
annunciations, ANNUNCIATE TROUBLE INDICATION must be selected
on the Console tab.
• [9] To announce telephone line and AC power status, ANNUNCIATE
PHONE-LINE/AC STATUS must be selected on the Console tab.
[10] The Console will only announce Home Mode when manually switched
from Away Mode using the HOME button.
• [11] To report missed reminder messages, the global REPORT MISSED
REMINDER option must be selected on the Reminder Messages tab and
the reminder message slot must have the SEND REPORT option selected.