Linear PERS-4200 Series Medical Alarms User Manual


 
23
11.6 Reminder Messages Tab
The PERS-4200 Console has a real-time clock calendar (RTCC)
function that can be set to the correct time and date, and then accessed
to schedule events and actions by the Console, including a scheduled
reminder message feature. Five pre-recorded reminder messages are
provided for this function and are included as part of each installed
language library. There are nine programmable message time slots to
use to set the reminder message types and schedule times.
IMPORTANT! THE CONSOLE’S TIME AND DATE MUST BE SET PRIOR
TO USING THE REMINDER MESSAGE FEATURE.
All reminder messages (including alarm and system test reminder) are
enabled only in Home Mode and Night Mode. They are disabled when in
Away Mode.
The PERS provider can schedule events for these reminder messages
as a one-time reminder, or as a recurring daily, weekly, or monthly event.
When the programmed event time is reached, the scheduled reminder
message is announced and if enabled, repeats once every three minutes
unless silenced by pressing the CANCEL button. When the CANCEL
button is pressed to silence the announcement, the Console will sound
a reminder chime.
A 15 or 30-minute timeout interval can be programmed as a setting for all
reminder messages. If the reminder is not acknowledged prior to expiration
of the timeout interval, a missed reminder event report can be sent to the
Central Station (if reporting of missed reminder messages is enabled).
If multiple reminder messages are scheduled at the same time or in the
same timeout interval, they will all be announced sequentially and at the
same three minute intervals, based on the fi rst message annunciated.
Pressing the CANCEL button cancels all of the reminder messages
within the same timeout interval.
Reminder Settings
The reminder settings globally affect all nine programmable reminder
message time slots.
Report Missed Reminder
The Console will provide voice prompts during the 15 or 30 minutes prior
to message reminder window expiring (set by programming).
Upon expiration of message reminder window the following will occur if
the REPORT MISSED REMINDER check box is checked.
1. The Console will activate and send an reminder message timeout
report to the Central Station. If the missed reminder is a system test
reminder, an automatic test report will be sent with status of the
system. 2-way audio will not be initiated.
2. Upon receipt and processing of the alarm transmission, a 2-way audio
session will begin (if enabled).
To enable missed reminder message reporting, check the REPORT
MISSED REMINDER check box.
Audio Replay During Timeout
The factory default will replay the reminder message every three minutes
until the message is acknowledged or times out.
To suppress replaying the reminder messages, un-check the AUDIO
REPLAY DURING TIMEOUT check box.
RA4200 Reminder Messages Tab