JVC DT-V2000SU Sleep Apnea Machine User Manual


 
11
You can adjust the picture distortion.
This function can be set when an INPUT A component (COMPO.)
signal or INPUT B (VIDEO) signal is input with the underscan size
(UNDER) selected or when an INPUT A RGB signal or INPUT C PC
(RGB) signal is input.
1 Press the MENU
MENU
button.
The <MAIN MENU> screen appears.
2 Press the SELECT
SELECT
button to select the
[DISTORTION ADJ.] item.
The selection mark (
4
) moves to
the [DISTORTION ADJ.] item.
3 Press the VOLUME/
ENTER
button.
The <DISTORTION ADJ.> screen
appears.
4 Press the SELECT
SELECT
button to select
the desired adjustment
item.
The selection mark (
4
) moves to
the adjustment item.
5 Perform adjustment with the VOLUME/
ENTER
/ buttons.
* Adjustable range: 60 +60
PICTURE DISTORTION
ADJUSTMENT
<MAIN MENU> screen
<MAIN MENU> screen
<DISTORTION ADJ.> screen
<DISTORTION ADJ.> screen
Items VOLUME/ENTER Contents
buttons
PINCUSHION
Indents both horizontal sides of the picture
(60 p +60)
Swells both horizontal sides of the picture
(60 [ +60)
PIN. BALANCE
Indents the right side of the picture and
swells the left side of the picture
(60 p +60)
Indents the left side of the picture and
swells the right side of the picture
(60 [+60)
PARALLELO-
Moves the upper side of the picture to
GRAM
the left and the lower side of the picture
to the right
(60 p +60)
Moves the upper side of the picture to
the right and the lower side of the
picture to the left
(60 [ +60)
TRAPEZOID
Shortens the upper side of the picture
(60 p +60)
Expands the upper side of the picture
(60 [ +60)
(
)
(
)
(
)
(
)
PINCUSHION: adjusts the pincushion distortion
PIN. BALANCE: adjusts the balance of the pincushion distortion
PARALLELOGRAM: adjusts the parallelogram distortion
TRAPEZOID: adjusts the trapezoid distortion
SELECTING [ sub menu] IN PROCEDURE 4
You can also adjust items in procedure 5 with only the
selected item displayed. Use this if the full menu screen
makes it difficult to observe the monitor image.
1Select the [ sub menu] item in procedure 4.
2Press the VOLUME/
ENTER button.
The <sub menu> screen appears.
(A single item is displayed at a
time.)
3Press the SELECT
SELECT
button to
select the desired item.
4Perform adjustment with the
VOLUME/ENTER
/
buttons.
RESETTING ITEMS TO THEIR FACTORY-SET (INITIAL)
VALUES
You can reset the <DISTORTION ADJ.> items to their
factory-set (initial) values.
1Select the [ reset] item in procedure 4.
2Press the VOLUME/ENTER
button.
The <reset> screen appears.
3Perform adjustment with the
VOLUME/ENTER button or
the MENU
MENU
button.
VOLUME/ENTER
button Values are reset.
MENU
MENU
button Reset is aborted
(values are unchanged).
* The screen from procedure 4 reappears.
6 After adjustment is complete, press the
MENU
MENU
button twice to exit the menu
screen.
Notes:
The [DISTORTION ADJ.] item may not be displayed
depending on which input mode (INPUT SELECT) is
selected. In this case, adjusting the picture distortion may be
impossible.
The menu screen automatically disappears when no
operation is performed after about 30 seconds.
When a prompt appears in the menu screen, it does not
disappear until the operation requested is performed.
Up to 12 different RGB signals input to INPUT A or INPUT C
are automatically stored in memory (User Memory).
When the 13th signal is input, the signal first stored in
memory is replaced with the new one.
(Refer to User Memory for RGB Input on page 14.)
<sub menu> screen
<reset> screen
00.12.20, 0:39 PM11