7.2 Electrical
For additional troubleshooting information and explanation of error codes, refer to the individual Electronics Manual supplied with
each personal transporter.
Information Gauge Diagnostics
The joystick information gauge acts as a service indicator to give
indications of the type of fault or error detected by the control
module. When a fault is detected, the personal transporter may
stop and not drive. The LEDs on the information gauge will flash
rapidly. The number of flashes indicates the nature of the error. If
multiple errors are found, only the first error encountered by the
control module will be displayed.
NUMBER OF
FLASHES
ERROR CODE DESCRIPTION
POSSIBLE SOLUTION
1
User Fault
Release joystick to neutral and try again.
2
Battery Fault
Charge the batteries.
3 Left Motor Fault Contact Invacare/Dealer for service.
4 Right Motor Fault
Contact Invacare/Dealer for service.
5
Left Park Brake Fault
Ensure brake lever is in the drive position before turning on the personal
transporter. Ensure motor cable is plugged into the controller.
Contact Invacare/Dealer for service.
6
Right Park Brake Fault
Ensure brake lever is in the drive position before turning on the personal
transporter. Ensure motor cable is plugged into the controller.
Contact Invacare/Dealer for service.
48 1171794-B