Genie Z-80, Z-60 Personal Lift User Manual


 
Part No. 82258 Genie Z-80/60 17
Operator's ManualFirst Edition · Third Printing
FUNCTION TESTS
At the Platform Controls
Test Emergency Stop
22 Turn the key switch to platform control.
23 Push in the platform red Emergency Stop button
to the off position.
Result: The engine should turn off and no
functions should operate.
24 Pull out the red Emergency Stop button and
restart the engine.
Test the Hydraulic Oil Return Filter
25 Press the engine idle speed select button until
the indicator light next to high idle (rabbit
symbol) is on.
26 Locate and check the
hydraulic filter condition
indicator.
Result: The filter should
be operating with the
plunger in the green
area.
27 Press the engine idle speed select button until
the indicator light next to foot switch activated
high idle (rabbit and foot switch symbol) is on.
Test the Horn
28 Push the horn button.
Result: The horn should sound.
Test the Tilt Sensor Alarm
29 Push a button, such as the engine RPM button
or the fuel select button.
Result: The alarm should sound at the platform
controls.
Test the Foot Switch
30 Push in the platform red Emergency Stop button
to the off position.
31 Pull out the red Emergency Stop button to
the on position but do not start the engine.
32 Press down the foot switch and attempt to start
the engine by pushing the engine start button.
Result: The engine should not start.
33 Do not press down the foot switch and restart
the engine.
34 Do not press down the foot switch and test each
machine function.
Result: No machine functions should operate.
Test Machine Functions
35 Press down the foot switch.
36 Activate each machine function control handle,
toggle switch or button.
Result: All functions should operate through a
full cycle.