Genie Z-80, Z-60 Personal Lift User Manual


 
Part No. 82258 Genie Z-80/60 15
Operator's ManualFirst Edition · Third Printing
Function Tests
Fundamentals
The function tests are designed to discover any
malfunctions before the machine is put into
service. The operator must follow the step-by-step
instructions to test all machine functions.
A malfunctioning machine must never be used. If
malfunctions are discovered, the machine must be
tagged and removed from service. Repairs to the
machine may only be made by a qualified service
technician, according to the manufacturer's
specifications.
After repairs are completed, the operator must
perform a pre-operation inspection and function
tests again before putting the machine into service.
Do Not Operate Unless:
You learn and practice the principles of safe
machine operation contained in this operator's
manual.
1 Avoid hazardous situations.
2 Always perform a pre-operation
inspection.
3 Always perform function tests prior to
use.
Know and understand the function tests
before going on to the next section.
4 Inspect the workplace.
5 Only use the machine as it was intended.
1 Select a test area that is firm, level and free of
obstruction.
At the Ground Controls
2 Turn the key switch to ground control.
3 Pull out the red Emergency Stop button to
the on position.
Result: The LCD screen will come on and
display no error messages. The beacon (if
equipped) should flash.
Note: In cold climates, the LCD readout screen will
need to warm up before the display appears.
4 Start the engine. See Operating Instructions
section.
Test Emergency Stop
5 Push in the red Emergency Stop button to the
off position.
Result: The engine should turn off and no
functions should operate.
6 Pull out the red Emergency Stop button to
the on position and restart the engine.
Test the Machine Functions
7 Do not press and hold a function enable/speed
select button. Attempt to activate each boom
and platform function button.
Result: No boom and platform functions should
operate.
8 Press and hold a function enable /speed select
button and activate each boom and platform
function button.
Result: All boom and platform functions should
operate through a full cycle. The descent alarm
(if equipped) should sound while the boom is
lowering.