Genie Z-80, Z-60 Personal Lift User Manual


 
16 Genie Z-80/60 Part No. 82258
Operator's Manual First Edition · Third Printing
FUNCTION TESTS
Test Auxiliary Controls
9 Shut the engine off.
10 Pull out the red Emergency Stop button to the
on position.
11 Simultaneously push and hold the auxiliary
power button and push each boom function
button.
Note: To conserve battery power, test each
function through a partial cycle.
Result: All boom functions should operate.
Test the Tilt Sensor
12 Push one of the LCD
screen buttons until
TURNTABLE LEVEL
SENSOR X-DIRECTION appears.
Result: The LCD screen should display the
angle in degrees.
13 Push one of the LCD screen buttons until
TURNTABLE LEVEL SENSOR Y-DIRECTION
appears.
Result: The LCD screen should display the
angle in degrees.
14 Push one of the LCD screen buttons until
PLATFORM LEVEL SENSOR DEGREES
appears.
Result: The LCD screen should display the
angle in degrees.
Test the Operating Envelope
15 Push one of the LCD screen
buttons shown until PRI
BOOM ANGLE is
displayed.
16 Raise the primary boom and observe the LCD
screen.
Result: The primary boom should raise and the
LCD screen should display the primary boom
angle in degrees from 35 to 68. The primary
boom should stop when the screen reads 68
degrees.
17 Lower the primary boom.
18 Simultaneously push the
LCD screen buttons shown
to activate status mode.
19 Push one of the LCD screen
buttons shown until SEC
BOOM ANGLE is
displayed.
20 Push and hold the secondary boom up/extend
button.
Result: The secondary boom should raise and
the LCD screen should display:
0DEG
>0DEG
AT65DEG
AT 0 FT
>0 FT
>22 FT
The secondary boom should raise and then
extend. The secondary boom should not extend
until it is fully raised.
21 Push and hold the secondary boom down/retract
button.
Result: The secondary boom should fully retract
and then lower. The secondary boom should not
lower unless it is fully retracted.