Epson XK3190-H2B Scale User Manual


 
Press keys in the order of <<Verify>>…<<Verify>>, <<modify>>, <<Figure>> and
<<Enter>> to enter or edit a calibrated data.
(Initializing) zeroing scopes (P16 or P30) can be achieved by using above-mentioned
method only, with 2-100(%Max) as valid value scope. Non-linearity tolerance is the
difference between zero point and 50%F.S after the full scale is calibrated.
Non-linearity edited value (15) is the negative of non-linearity tolerance.
26 <<Type>><<Figure>> Set new category number. After press <<Type>>, the category
cursor twinkles.
27 <<Type Cancel>> Category number and weighing serial number disappear and then
accumulation and data saving can not be executed.
28 <<COMM >> switch of the communication function to the upper computer. Marked by
COMM
29 <<Accum>> Record and accumulate the present weight, then go to accumulation
display mode.
30 <<Memo recall>>Display the accumulated weight of the present category. Accumulated
value is marked by SUM.
31 <<Memo clear>> Clear the weight record of the present category and the accumulated
weight, and then return to weighing mode. It only works in accumulation state.
32 << Memo recall>> <<Total clear>>Clear all weighing records and accumulated value.
33 <<COMM>><<memo recall>><<Mode Tranl>>Transfer the weight list to upper
computer.
Data Printing Format
1. Micro-printer printing format
a) Heading printing format
b) Data printing format
State Data format
Net weight NYZZXXXXXXXX kg
Gross weight GYZZXXXXXXXX kg
Tare PZL XXXXXXXX kg
Weight limit XZL XXXXXXXX kg
Accumulation ……………………………..
SUM XXXXXXXX kg
Date time XX year XX month XX day XX hour XX minute
Weight A/D inner code A/D XXXXXXXX
Parameter YY PYY XXXXXXXX
Weight list
Xk3190-H2B 1.02
16:39 15th Oct. 2003
Serial No. Weight Unit