Epson XK3190-H2B Scale User Manual


 
“Y” represents Type No. , “YY” represents Para. No., “ZZ” represents Serial No., “XXXXX”
represents Data
XX.XX.XX.XX.XX represent year, month, day, hour, minute respectively
2. External printer printing format
Note: Only the printer with Chinese character database is applicable
Heading format
Weight printing format:
“G” represents gross weight “N” represents net weight
Other printing formats are similar to micro-printer’s
List printing as follows:
“G” represents gross weight “N” represents net weight
V Error message from wrong operation
Usually, wrong operation message is caused by illegal operation or the parameters entered
beyond the preset range.
Error message Comments
Err 21 Calibrated data lost, input or calibrate again
Err 23 Wrong 24C256 stored data checking, may be caused by turning off power supply switch
first instead of indicatior.
Err 25 Error program checking codes, rewrite them
Err 26 Error accumulated value, the value of this type has been deleted
Err 27 The figure displayed on scoreboard exceeds 6 digits (including decimal), the problem
Weight list
Time : xxxx year xx month xx day xx hour xx minute xx second
Type Sign : xxxxxxxx Indicator model: XK3190-H2B 1.02
Type NO. Serial NO. weighing time : weight
GO 01 08:10:20 15th Jan. 2004 2450 kg
GO 01 08:16:30 15th Jan. 2004 3100 kg
……. ………………………………………………………………………………………..
Total weight: 5550 kg
G 0 01 08h:10m:20s 15th Jan. 2004 2450 kg
Weight list
Time :xxxx year xx month xx day xx hour xx minute xx second
Type sign : xxxxxxxx Indicator model No. : XK3190-H2B 1.02
Type NO. serial NO. weighing time : weight