Epson XK3190-H2B Scale User Manual


 
press. Press <<Exit>>or <<Enter>> to return to weighing mode. If a programmable data
needs to be modified, press keys in the order of <<Modify>><<Figures>><<Enter>> to
enter new data. Data order is displayed as follows:
Pressing times Reminding symbols Data meaning
1 YXX printing is not allowed in weighing mode of
division=0.1e
2 A/D Weight A/D internal code
3 P09 Display the weight in zero point
4 P10 Display zero point upon powered on
5 P11 Calibrate zero point internal code
6 F Full Scale
7 E Check division 0.0150, 12 options in total
8 P14 Displaying ratio
9 P15 Displaying Non-linearity edited value within
the scope of –1%Max1%Max, weight unit
10 P16 Initial zeroing range 2100 unit: %Max.
This parameter determined the difference
between present load and calibrated zero
point with 20%Max as default in first
zero-setting upon powered on.
11 P17 Zero-tracing switch, 0 is off and 1 is on
12 P18 Weight unit:
0=t 1=kg 2=g 3=mg
13 P19 bit number
0=600 1=1200 2=2400 3=4800 4=9600BPS
14 P20 Communication mode:
0= constant sending 1= answer style
15 P21 Communication address:
1255
16 P22 Printer styles:
0=without Chinese characters database
1=with Chinese characters database (only
the printer with Chinese characters
database is applicable at present, this para.
does not work)
17 P23 The lighting time of the background light
1255, unit: Second. 0=no automatic off
18 P24 Scoreboard switch:
0=on 1=off
19 P25 RS232 switch
0= on 1=off
20 P26 Displaying divisions 0.0150 12 options
total
21 P27 Displaying Version No. For example: H2C