Bit 0 1 2 3 4 5 6 7 8 9 10
start d0 d1 d2 d3 d4 d5 d6 d7 sigh stop
bit G8 ------ G15 bit bit
(Figure 6.2) The second frame view
The third frame
1
0
bit 0 1 2 3 4 5 6 7 8 9 10
start d0 d1 d2 d3 d4 d5 d6 d7 sigh stop
bit bit bit
G0 --------- G7
(Figure 6.3 ) The third frame view
The first frame datum: sign bit is 0
X: D0, D1, D2--Decimal place (0~4)
Y: D3--- Weight sign (1—minus, 0—plus)
D4--- Spare
G18G16: Weight data
The second frame of data: sign bit is 0
G15G8: Weight data
The third frame of data: sign bit is 1
G7G0: Weight data
G0G18: The weight (net weight) is constructed from down upward in 19 bits binary system
code.
9. Charge
Charge the battery of indicator in time if the LoBAT character in the screen of the indicator
twinkles, which means that the battery of the indicator is low. Or the indicator will power off
automatically 3 minutes later. The back power switch should be off when the indicator
charged by the intelligent&quick charger H2CDQ, this can avoid the damage resulted from
impact on circuit of the power source from the big current. Before charging the battery in the
condition of no LoBAT twinkles, press discharging button to get battery discharge, and in this way,
battery capacity degradation can be effectively prevented
Charge the battery of scale body in time if the LoBAT character in the screen of the indicator
keeps lights, which shows the battery of the body is low. Or the scale body will power off 10
minutes later. Before charging the battery in the condition of no LoBAT twinkles, press
discharging button to get battery discharge, and in this way, battery capacity degradation can be
effectively prevented.