A SERVICE OF

logo

SC6000
A
V
USER INTERFACE
Ground
SC6000
A/B
B/
A
GND
V
S_INPUTS
Signal
PWO
Figure 44 - PNP Command Input Using System Power
V
USER INTERFACE
Ground
SC6000
A/B
B/
A
GND
V
S_INPUTS
Signal
PWO
Figure 45 - NPN Command Input Using System Power
Isolation between the command logic and the scanner is maintained by powering the inputs
with an external supply voltage (Vext). For convenience, the inputs can be powered using the
VS_INPUTS signal on the SC6000 (pin 9). In this case, however, the device is no longer
electrically isolated. The VS_INPUTS signal on the Extended I/O connector is short-circuit
protected.
The electrical features of these inputs are:
Maximum voltage 30 V
Maximum current 10 mA
Outputs
Six general purpose outputs are available.
Pin Name Function
6 OUT 1+ Configurable digital output 1 – positive pin
19 OUT 1- Configurable digital output 1 – negative pin
7 OUT 2+ Configurable digital output 2 – positive pin
20 OUT 2- Configurable digital output 2 – negative pin
8 OUT 3+ Configurable digital output 3 – positive pin
21 OUT 3- Configurable digital output 3 – negative pin
10 OUT 4+ Configurable digital output 4 – positive pin
23 OUT 4- Configurable digital output 4 – negative pin
11 OUT 5+ Configurable digital output 5 – positive pin
24 OUT 5- Configurable digital output 5 – negative pin
12 OUT 6+ Configurable digital output 6 – positive pin
25 OUT 6- Configurable digital output 6 – negative pin
The function of all six outputs can be defined by the user.
Refer to Genius™ Help On-Line for further details.
42