SOFTWARE CONFIGURATION
3
3.2.2 Alternative Slave Address Assignment
As alternatives to Network Setup through the Master, each Slave scanner can be assigned
an address through the following methods:
random address assignment from SC6000 to all slaves in the network by performing
the CASP™ procedure as described in par. 2.6.2;
address setting through the Local Device Network Settings item in the Device Menu
with the slave scanner connected to Genius™;
manual address setting through slave scanner keyboard (see par. “Internal Net” in the
relative Scanner Reference Manual for details);
3.3 GUIDE TO RAPID CONFIGURATION FOR DS8100 AND DX8200
SLAVE SCANNERS
1) Connect to each scanner Debug port and set a Lonworks Node address which must be
different and consecutive (i.e. 1, 2, 3, 4, etc.).
2) Make all the necessary PackTrack parameter settings.
3) Run Genius™ from the configuration PC. The following window appears asking to select
the configuration mode.
Figure 29 - Genius™ Wizard Opening Window
Select Advanced. The Wizard option is not currently available for SC6000.