4
4 MAINTENANCE
4.1 DATALOGIC AUTOMATIC REPLACEMENT PROCEDURE (DARP
TM
)
Once the system configuration has been completed, launch the DARP™ backup by one of
the following methods:
Using Genius:
Click on the DARP™ backup icon in the Device Network area. You will be prompted to select
the desired backup option (complete, all scanners, controller, or each single scanner).
Using the SC6000 keypad:
1. Press the <Ent> and <Menu> keys simultaneously to enter the Menu;
2. Use the <arrow> keys to move within the menu items;
3. In the <System> menu choose <Backup> and select the desired backup option
(complete, all scanners, controller, or each single scanner).
The SC6000 Controller will store the complete system configuration on the Compact Flash
card.
If a slave scanner has to be replaced, the corresponding configuration (node address, code
configuration, PackTrack™ configuration, etc.) is automatically downloaded by the SC6000
into the new scanner at the next system startup.
NOTE
Systems with DS8100 or DX8200 slave scanners must have been
installed according to the procedure in par. 3.3.
In case of SC6000 failure, the complete system configuration can be recovered from the
damaged SC6000 Compact Flash: by simply installing the old Compact Flash in the new
SC6000, the system configuration is automatically restored and the reading station is ready
to start working again.
CAUTION
Before removing the Compact Flash card, switch the SC6000 Controller off.
31