Invacare R51LXP Mobility Aid User Manual


 
SECTION 12—BATTERIES
Nutron® Series 57 Part No.1106645
FIGURE 12.6 Connecting Battery Cables - Direct Mount Method
1/4-20 Hex
Flange Locknut
POSITIVE (+)
Battery
Terminal/Post
1/4-20 x
7/8-inch Hex
Flange Screw
NEGATIVE (-) Battery
Terminal/Post
Detail “A” - Dual UI Batteries
CONNECT
CABLE RING
TERMINAL TO
THIS SIDE OF
TERMINAL/POST
Tie-Wraps
GREY Battery
Terminal Cap
NEGATIVE (-) Battery
Terminal/Post
POSITIVE (+)
Battery
Terminal/Post
ORANGE Battery
Terminal Cap
Detail “B” - Dual Group 22 NF Batteries
1/4-20 X 7/8-Inch
Hex Flange Screw
POSITIVE (+) Battery
Terminal/Post
NEGATIVE (-) Battery
Terminal/Post
POSITIVE (+) Red
Battery Cable
1/4-20 Hex
Flange
Locknuts
NEGATIVE (-) Black
Battery Cable
CONNECT
BATTERY CABLE
TO BATTERY
TERMINAL AS
SHOWN.
BLACK Battery
Terminal Cap
RED Battery
Terminal Cap
Tie-Wraps
NEGATIVE (-)
Battery
Terminal/Post
POSITIVE (+) Battery
Terminal/Post