Battery indicator control system fault display
e battery indicator also provides a diagnostic display. When a control system fault occurs, a set of
lights will flash. Use the picture at left below to identify the fault code (the number of lights flashing),
then see the system fault and appropriate action at the picture's right.
THE FOLLOWING SYSTEM FAULTS WILL PREVENT THE WHEELCHAIR FROM DRIVING.
SYSTEM
FAULT CHECK / ACTION
Low battery The battery needs charging or there is a bad connection to the
voltage batteries. Check the connections to the batteries and the controller
power connector. If the connections are good, try charging the battery.
Left motor The left motor has a bad connection. Ensure that the motor is
disconnected connected properly and the controller connectors are secure. If
problem persists, see dealer. (Check motor brushes)
Left motor The left motor has a short circuit to a battery connection. See dealer.
wiring fault (Check motor brushes)
Right motor The right motor has a bad connection. Ensure that the motor is
disconnected connected properly and the controller connectors are secure. If
problem persists, see dealer.
Right motor The right motor has a short circuit to a battery connection. See dealer.
wiring fault
Inhibit active The battery charger is preventing the controller from driving the
wheelchair. Disconnect charger from wheelchair.
Possible A joystick fault is indicated. Ensure that joystick is in neutral before
joystick fault turning ON/OFF switch on.
Possible A controller fault is indicated. Ensure that all Controller connections
controller are secure. If problem persists, see dealer.
fault
Possible The park brakes have a bad connection. Check the park brake &
park brake motor connections. Ensure that controller connections are secure.
fault If problem persists, call dealer.
Excessive This is usually caused by a poor battery connection. Check the
voltage controller and battery connections.
Communication A communication fault is indicated. Ensure that hand control cable is
fault securely connected and not damaged.
2 lights flashing rapidly
1 light flashing rapidly
3 lights flashing rapidly
4 lights flashing rapidly
5 lights flashing rapidly
6 lights flashing rapidly
7 lights flashing rapidly
8 lights flashing rapidly
9 lights flashing rapidly
10 lights flashing rapidly
7 lights + S flashing rapidly
battery level indicator
control system fault