The commands in this section allow you to make the following changes to the
waveform monitor:
H Select an input signal source
H Select which channel or channels to display
H Set the offset level for the Pb and Pr channels of the input signal
INput:SOUrce <SERIALA | SERIALB>
Selects the signal for display from the A or B rear-panel, loop-through inputs.
INput:SOUrce <SERIALA | SERIALB>
INput[:SOUrce]?
<SERIALA | SERIALB>
in:sou seriala
input:sou?
:INPUT:SOURCE SERIALA
Syntax
Arguments
Examples