Soehnle 7710 Microscope & Magnifier User Manual


 
English
5511
Printing
The Program Terminal 3020 can be connected to a printer via a serial port to print out scale chits.
Up to a max. of 15 print templates can be stored.
To design print templates with individual contents the Soehnle Professional service centres offer
service software for the 3020/3030.
Parameters listed below in the standard print templates can be used to design individual print templa-
tes. In addition, it is possible to copy organisation data (identifiers) and individual parameters such as
company names.
Please contact your Soehnle Professional service partner about your print template requirements.
Printing is triggered either by means of the Print key or via another print-command condition, such as
the F key.
Configuring the I/O port for the printer
Call up the setting menu using the Print key and F key (press simultaneously).
• The arrow points to "Program Settings" .
• Scroll to "I/O Ports" with the Tare key.
• Press the Print key: the arrow points to "Data transfer fixed values".
• Scroll to "I/O port 1" using the Tare key.
• Press the Print key: the arrow points to "Application".
• Press the Print key: the arrow points to "2795.11".
• Select the printer you wish to connect using the Tare key or F key.
• Confirm with the Print key.
Information: Soehnle Professional printers are stored in the memory as standard. However, it is also
possible to store other printers in the memory with the 3020/3030 service software.
Assign further parameters such as baud rate, data bits, parity and XON/XOFF as indicated in
the printer manual.
The parameters set at the factory are configured for Soehnle Professional printers.
Standard print template factory setting
The print-command keys can be assigned using the print templates in the service software. In the
factory setting the following print templates are already stored in the memory and assigned. They can
therefore be printed.
This standard print template is an example that shows which parameters are available.
Date 01.09.05
Time 09:13:28
Scale no. 02
Gross W 0,154 kg
Tare T 0,015 kg