SkyLink SA-001S Medical Alarms User Manual


 
7
To erase unwanted remote(s) or sensor(s) or control panel(s) from the Wireless
External Alarm will erase all learned devices from the Wireless External Alarm.
- Press and hold the Learn/Set button on the Wireless External Alarm for
8 seconds.
- While holding the Learn/Set button on the Wireless External Alarm until the
Learn/Set LEDs turn on. You may release the Learn/Set button when the
Learn/Set LED stay on.
- Press and hold the Learn/Set button again on the Wireless External Alarm for
2 seconds until it emits 2 beeps and all the LEDs ash twice. Now you may
release the ‘Learn’ button.
- All the learned devices have been erased.
User can customize the alarm period from 30 seconds up to 10 minutes. The factory
default of the alarm period is 3 minutes.
- Press and hold the Learn/Set button on the Wireless External Alarm for
5 seconds, you may release the Learn/Set button while all the LEDs turn on.
- While the PWR and Learn/Set LED stay on, press the Learn/Set button once
on the Wireless External Alarm, the LEDs ash once indicating the alarm
period is set to 30 seconds.
- If you would set the other alarm period, continue to press the Learn/Set button.
Refer to the table below for the alarm period. The LEDs will ash corresponding
to the number you pressed the Learn/Set button.
1- 30 seconds
2- 60 seconds
3- 3 minutes
4- 5 minutes
5- 10 minutes
- Press and hold the Learn/Set button to conrm your setting. You will hear
2 beeps and the LEDs will ash twice indicating the alarm period is now
programmed to the Wireless External Alarm.
PrOgrAmmINg – ErAsE rEmOTE Or sENsOr Or cONTrOL
PANEL FrOm ThE WIrELEss ExTErNAL ALArm
PrOgrAmmINg – ALArm sOuNd durATION