Invacare Torque SP RWD Mobility Aid User Manual


 
Part No. 1104849 133 3G Storm Series
®
Wheelchairs
1. Determine the desired mounting
position of the gearless/brushless
motor. Refer to ACCEPTABLE
MOUNTING POSITIONS FOR THE
GEARLESS/BRUSHLESS MOTOR in
this section of the manual.
2. Remove the 22NF battery box or
group 24 battery boxes. Refer to
REMOVING/INSTALLING BATTERY
BOXES in SECTION 9 of this manual.
3. If necessary, remove the battery box
tray. Refer to REMOVING THE
BATTERY BOX TRAY in this section
of the manual.
4. Remove the drive wheel from the
wheelchair. Refer to REMOVING/
INSTALLING DRIVE WHEELS in
SECTION 12 of this manual.
5. Loosen the adjustment screw that secures the motor release handle to the brake
release shaft.
6. Remove the four (4) mounting screws and washers that secure the motor to the
suspension arm.
7. Slide the motor forward or backward to the desired mounting position.
8. Secure the motor to the mounting position determined in STEP 1 and secure with
the four (4) existing mounting screws and washers. Torque to 13 ft-lbs.
9. Securely tighten adjustment screw.
10. Reinstall the drive wheel to the wheelchair. Refer to REMOVING/INSTALLING
DRIVE WHEELS in SECTION 12 of this manual.
11. Repeat STEPS 1-9 for opposite side of wheelchair.
12. If necessary, reinstall the battery box tray. Refer to REMOVING THE BATTERY
BOX TRAY in this section of the manual.
13. Install the 22NF battery box or group 24 battery boxes. Refer to REMOVING/
INSTALLING BATTERY BOXES in SECTION 9 of this manual.
RWD WHEELCHAIRS SECTION 15
RWD WHEELCHAIRS
Adjustment
Screw
FIGURE 13 - REPOSITIONING THE
MOTOR - REPOSITIONING THE
STANDARD GEARLESS/
BRUSHLESS MOTOR -
BEFORE 1/26/04
Motor
Release
Lever
Brake Release
Shaft
Mounting Screws
Washer
Suspension Arm
Motor