SECTION 7—ARMS
Xtra™ 48 Part No 1026793
Adjusting T-Arm Depth
NOTE: For this procedure, refer to FIGURE 7.8.
1. Remove the two (2) phillips screws that secure the arm pad to the arm tube.
2. Remove the two (2) socket screws that secure the arm tube to the T-arm post.
3. Reposition the arm tube on the T-arm post:
• Desk Length Arms - to one (1) of three (3) positions depending on the desired arm
pad depth.
• Full Length Arms - to one (1) of five (5) positions depending on the desired arm
pad depth.
NOTE: Additional positions are obtainable by turning the arm tube 180°.
4. Re-secure the arm tube to the T-arm post with the two (2) socket screws. Torque to 60-
70 in./lbs.
5. Reattach the arm pad to the arm tube with the two (2) phillips screws. Tighten
securely.
6. Repeat for the opposite side, if necessary.
FIGURE 7.8 Adjusting T-Arm Depth
Phillips Screw
Arm Pad
Phillips
Screw
Arm Tube
NOTE: If
necessary, turn
arm tbue 180°
to obtain two
(2) positions.
T-Arm
Socket
NOTE: Desk length arm
shown for clarity.