Graco 3A1331C Blood Pressure Monitor User Manual


 
Appendix B - Breakout Module Connections
The following provides descriptions and pins of all
connectors used on the breakout module. These can
be used if the components are being wired directly
to the breakout module.
LCM Power
Cable 1 Blue
Pin Description Pin Number
M12
Connector, 5
pin, Female, A
code
Shield
1
Phoenix
Contact Part
Number
1694224
Power (12 V or
24 V)
2
Ground 3
CAN +
4
CAN -
5
Solenoi
dAir
Connect
or 3
Red
Pin Description Pin Number
M12
Connector, 5
pin, Female, A
code
Solenoid Air
Digital Output
4
Phoenix
Contact Part
Number
1542761
Not Used 2
Not U
sed
1
Digital Output
Ground
3
Not Used
5
Light Tower
Connector 4—
Green
Pin Description Pin Number
M12
Connector, 5
pin, Female, A
code
Lamp 1 Green
Digital Output
4
Phoenix
Contact Part
Number
1542761
Lamp 2 Yellow
Digital Output
2
Not Used 1
Digital Output
Ground
3
Lamp 3 Red
Digital Output
5
APressure
Transducer 6—
Blue
Pin Description Pin Number
M12
Connector, 5
pin, Female, B
code
Pressure
Differential
Analog Input
+
4
Phoenix
Contact Part
Number
1543650
Pressure
Differential
Analog Input
-
2
Pressure
Power (5 volt)
1
Pressure
Ground
3
Shield Analog
5
3A1331C
27