Connect Air Hoses and Cables
Reference 262940 Line Power Kit, page 4 and
262942 Air Turbine Kit, page 5 for air hose and
cable connections.
Use tie wraps provided to secure hose and cables.
For turbine kit 262942, route exhaust hose down cart
leg and secure.
262942: Secure solenoid cable (F) to air hoses
with tie wrap. Route exhaust hose (J) down the
inside of the cart leg and secure with tie wrap.
262940: Route solenoid cable (F) behind the air
hose and secure with tie wrap.
Startup
1. Refer to your XP Sprayer Operation manual for
sprayer startup instructions.
Note
The pressure monitor kit modifies XP
sprayers. However, the operation
procedures from the XP sprayer
Operation manual still apply.
2. Turn on power.
a. For 262940: Turn on power switch (9)
located on the electronics box.
b. For 262942: Open ball valve (22) located
outside of the electronics box.
3. Wait for the power up screen to complete. The
Circulation Mode screen will display. The light
tower will briefly flash green, yellow, and red to
verify the lights before staying on yellow. Wait for
the run screen to appear.
4. Set system parameters before spraying.
These can be changed as necessary.
Press
to enter Setup Mode. For
more information and default settings, see
Setup Mode Details, page 22.
5. In Circulation Mode, all alarms are disabled
except for the air solenoid detection, pressure
sensor failure, and high pressure alarms.
Note
In Manual Bypass Mode you can still
spray when one pressure transducer
fails, but the control no longer monitors
the pressures and will not shut off the
sprayer. This is for emergency only.
a. To enter Manual Bypass Mode, set the
minimum spray pressure equal to the
maximum spray pressure on setup screen
2. In Manual Bypass Mode, the system can
never get into Spray Mode. The event code
EVC1 is displayed on the information screen
and logged in the error log. The yellow light
is always on and all alarms are ignored.
b. To exit Manual Bypass Mode, set the
mimimum spray pressure and maximum
spray pressure to different spray pressures.
Event code EVC0 will log in the error log
when Bypass Mode is disabled.
6. Press
to start the air motor. The red LED
will turn on and the motor will start. Only spray
when the green light on the light tower is on. For
more information about the LCM run screens,
see Run Mode Details, page 25.
Shutdown
1. Press . The red LED will turn off and the
motor will stop.
2. Turn off the power switch or ball valve on the
outside of the electronics box.