Cause Solution
Deviations
Ran out of B side
material.
Refill hopper or
change drum.
Cavitating B side
pump.
Warm material or add
feed pressure.
B material leaking. Follow pump
troubleshooting in
XP70 Sprayer manual.
No mix manifold B
side restriction.
Add restriction to B
side on mix manifold
to balance pressures.
J3AX Differential Pressure
(A>B)
Yellow
Flashing
Asidehoseistoo
small.
Change to larger hose
size.
Ran out of A side
material.
Refill hopper or
change drum.
Cavitating A side
pump.
Warm material or add
feed pressure.
A material leaking. Follow pump
troubleshooting in
XP70 Sprayer manual.
Too much restriction
on mix manifold B side
restriction.
Reduce restriction
to GB side on mix
manifold.
* B side hose too
small.
Change to larger hose
size.
J3BX Differential Pressure
(B>A)
Yellow
Flashing
* No B side offset in
control setup.
Add B side offset in
setup screen.
Events and Advisories
EERX
Under Minimum Spray
Pressure, Circulation,
Loading
Yellow
Under minimum spray
pressure.
Normal for circulation
mode.
EVC0
Manual Bypass Mode
Enabled and Logged.
Minimum Pressure =
Maximum Pressure
Yellow
Manual Bypass Mode
Reset minimum
spray pressure and
maximum spray
pressure in Setup
Mode.
EVC1
Manual Bypass Mode
Disabled and Logged
Event log only
ELCX
Control Power Up
Timer set to zero
in Log
Event log only
* Remote mix manifold applications only.