Appendix A— User Interface Display
Topics Covered in this Chapter
SetupModeDetails
RunModeDetails
Information Screen
Setup Mode Details
Setup mode screens enable user to view or modify
system configuration data. User can set:
Units of pressure
Differential pressure warning value
Differential pressure alarm value
High pressure limit value
Minimum spray pressure value
Normal B pressure offset value
Changing Setup Parameters
1. Navigate to a Setup screen by pressing . Then
use
to select a screen.
2. Press
to access fields and make changes.
3. Pre
ss
to navigate to the field that you want
to change. Press
to edit data.
4. Press
to select digits.
5. Press
to accept the new values or press
to cancel.
6. Press
to exit edit mode.
SetupScreen1
Setup screen 1 enables users to set units of
measurement that will display on other screens,
differential warning and differential alarm.
Additionally, this screen displays the software
number and version. Refer to the following table for
more information.
Icon Function
Warning Pressure
Adjust the differential pressure
deviation setpoint. The yellow light
on the light tower will be flashing.
Default: 400 psi
Range: 0–2000 psi
Alarm Pressure
Adjust the differential pressure alarm
setpoint. The red light on the light
tower will be solid on.
This is the main setting that
determines how far apart your A and
B pressures can be before shutting
down the machine. If the machine
shuts down too easily, increase this
to a higher setpoint.
Default: 600 psi
Range: 0–2000 psi