ETA Systems FC01-LQ Oxygen Equipment User Manual


 
Resistive load
Max. admissible switching capacity: 50 W
Max. admissible switching current: 1 A
Max. admissible continuous current: 1 A
Max. admissible switching voltage: 50 V
Contact life at 1 A: 3 x 10
5
cycles
Inductive load - with safety circuit - AC voltage
Max. admissible switching capacity: 125 VA
Max. admissible switching current: 1.25 A
Max. admissible continuous current: 1.25 A
Max. admissible switching voltage: 100 V
Contact life cos = 0.5: 2.4 x 10
5
cycles
Insulation voltage: signal contact - central electronic unit DC 500 V
signal contact - signal contact DC 500 V
8.4.2 Transistor outputs (DC)
Pin selection: Signal name Pin XAH Polarity
/ ERROR emitter 1 -
/ ERROR collector 2 +
/ BUSY / PULSE emitter 3 -
/ BUSY / PULSE collector 4 +
Limit Switch 2 emitter 5 -
Limit Switch 2 collector 6 +
Limit Switch 1 emitter 7 -
Limit Switch 1 collector 8 +
Voltage level
Low level - active: U
ce
< 0.8 V at I
C
< 10 mA
U
ce
< 1 V at I
C
< 100 mA
High level - passive: U
ce
< 48 V
U
ce max
= 60 V
max. leakage current 25 µA
Reverse polarity protection: yes
Short circuit protection: yes
Flow Meter FC01-LQ Flow Meter FC01-LQ
Technical data 51 Technical data 51
Resistive load
Max. admissible switching capacity: 50 W
Max. admissible switching current: 1 A
Max. admissible continuous current: 1 A
Max. admissible switching voltage: 50 V
Contact life at 1 A: 3 x 10
5
cycles
Inductive load - with safety circuit - AC voltage
Max. admissible switching capacity: 125 VA
Max. admissible switching current: 1.25 A
Max. admissible continuous current: 1.25 A
Max. admissible switching voltage: 100 V
Contact life cos = 0.5: 2.4 x 10
5
cycles
Insulation voltage: signal contact - central electronic unit DC 500 V
signal contact - signal contact DC 500 V
8.4.2 Transistor outputs (DC)
Pin selection: Signal name Pin XAH Polarity
/ ERROR emitter 1 -
/ ERROR collector 2 +
/ BUSY / PULSE emitter 3 -
/ BUSY / PULSE collector 4 +
Limit Switch 2 emitter 5 -
Limit Switch 2 collector 6 +
Limit Switch 1 emitter 7 -
Limit Switch 1 collector 8 +
Voltage level
Low level - active: U
ce
< 0.8 V at I
C
< 10 mA
U
ce
< 1 V at I
C
< 100 mA
High level - passive: U
ce
< 48 V
U
ce max
= 60 V
max. leakage current 25 µA
Reverse polarity protection: yes
Short circuit protection: yes